| HP ProCurve Switch 2510G-48 (J9280A) | HP ProCurve Switch 2510G-24 (J9279A) | HP ProCurve Switch 2510-48 (J9020A) |
|---|
| Ports |
| 44 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
4 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port or an open mini-GBIC slot (for use with mini-GBIC transceivers)
| 20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
4 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port or an open mini-GBIC slot (for use with mini-GBIC transceivers)
| 48 RJ-45 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
2 RJ-45 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
1 RJ-45 serial console port
2 open mini-GBIC (SFP) slots
|
| Physical characteristics |
| Dimensions | 12.7(d) x 17.4(w) x 1.7(h) in. (32.26 x 44.2 x 4.32 cm) (1U height) | 12.7(d) x 17.4(w) x 1.7(h) in. (32.26 x 44.2 x 4.32 cm) (1U height) | 9.3(d) x 17.42(w) x 1.73(h) in. (23.62 x 44.25 x 4.39 cm) (1U height) |
| Weight | 8.6 lb. (3.9 kg) | 7.21 lb. (3.27 kg) | 6.05 lb. (2.74 kg), Fully loaded |
| Memory and processor |
| Processor | MIPS @ 264 MHz, 16 MB flash, 64 MB SDRAM; packet buffer size: 1.5 MB | MIPS @ 264 MHz, 16 MB flash, 64 MB SDRAM; packet buffer size: 0.75 MB | MIPS 32 @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 512 KB |
| Mounting |
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
| Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
| Latency | < 5.4 µs (FIFO 64-byte packets) | < 5.6 µs (FIFO 64-byte packets) |
|
| 100 Mb Latency |
|
| < 4.9 µs (64-byte packets) |
| 1000 Mb Latency |
|
| < 2.9 µs (64-byte packets) |
| Throughput | up to 71.4 million pps | up to 35.7 million pps | up to 13 million pps (64-byte packets) |
| Switching capacity | 96 Gbps | 48 Gbps | 17.6 Gbps |
| MAC address table size | 8,000 entries | 8,000 entries | 8,000 entries |
| Environment |
| Operating temperature | 32°F to 113°F (0°C to 45°C) | 32°F to 113°F (0°C to 45°C) | 32°F to 113°F (0°C to 45°C) |
| Operating relative humidity | 15% to 95% @ 104°F (40°C), non-condensing | 15% to 95% @ 104°F (40°C), non-condensing | 15% to 95% @ 104°F (40°C), non-condensing |
| Non-operating/Storage temperature | -40°F to 158°F (-40°C to 70°C) | -40°F to 158°F (-40°C to 70°C) | -40°F to 158°F (-40°C to 70°C) |
| Non-operating/Storage relative humidity | 15% to 90% @ 149°F (65°C), non-condensing | 15% to 95% @ 149°F (65°C), non-condensing | 15% to 90% @ 149°F (65°C), non-condensing |
| Altitude | up to 10,000 ft. (3 km) | up to 10,000 ft. (3 km) | up to 15,000 ft. (4.6 km) |
| Acoustic | Power: 40.5 dB | Power: 40.3 dB | Power: 43.6 dB; DIN 45635T.19 per ISO 7779 |
| Electrical characteristics |
| Achieved Miercom Certified Green Award |
|
|
| Maximum heat dissipation | 341 BTU/hr (360 kJ/hr) | 164 BTU/hr (173 kJ/hr) | 92 BTU/hr (97 kJ/hr) |
| Voltage | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC | 100-127 / 200-240 VAC |
| Current | 1.5 A | 1.0 A | 1.2 / 0.7 A |
| Maximum power rating |
|
| 27 W |
| Power output | 92 W | 48 W |
|
| Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz |
| Notes |
|
| Maximum
power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure
with fully loaded PoE (if equipped), 100% traffic, all ports plugged in,
and all modules populated. |
| Safety |
| cUL (CSA 22.2 No. 60950) UL 60950-1 IEC 60950 EN 60950
| cUL (CSA 22.2 No. 60950) UL 60950-1 IEC 60950 EN 60950
| cUL (CSA 22.2 No. 60950) UL 60950-1 IEC 60950 EN 60950
|
| Notes |
| When
using mini-GBICs with this product, mini-GBICs with revision "B" or
later (product number ends with the letter "B" or later, e.g., J4858B,
J4859C) are required.
| When using
mini-GBICs with this product, mini-GBICs with revision "B" or later
(product number ends with the letter "B" or later, e.g., J4858B, J4859C)
are required.
|
|