HP ProCurve Switch 2510-24
(J9019B) |
HP ProCurve Switch 2510-48
(J9020A) |
HP ProCurve Switch 2510G-24
(J9279A) |
| Ports |
| |
24 RJ-45 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
2 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port
or an open mini-GBIC slot (for use with mini-GBIC transceivers)
|
48 RJ-45 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX)
Media Type: Auto-MDIX
Duplex: half or full
2 RJ-45 auto-sensing 10/100/1000 ports (IEEE 802.3 Type
10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
1 RJ-45 serial console port
2 open mini-GBIC (SFP) slots
|
20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)
Media Type: Auto-MDIX
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
4 dual-personality ports
each port can be used as either an RJ-45 10/100/1000 port
or an open mini-GBIC slot (for use with mini-GBIC transceivers)
|
| Physical characteristics |
| Dimensions |
9.3(d) x 17.42(w) x 1.73(h) in. (23.62 x 44.25 x 4.39 cm) (1U height) |
9.3(d) x 17.42(w) x 1.73(h) in. (23.62 x 44.25 x 4.39 cm) (1U height) |
12.7(d) x 17.4(w) x 1.7(h) in. (32.26 x 44.2 x 4.32 cm) (1U height) |
| Weight |
4.89 lb. (2.22 kg), Fully loaded |
6.05 lb. (2.74 kg), Fully loaded |
7.21 lb. (3.27 kg) |
| Memory and processor |
| Processor |
MIPS 32 @ 264 MHz, 8 MB flash, 64 MB SDRAM; packet buffer size: 384 KB |
MIPS 32 @ 300 MHz, 16 MB flash, 128 MB SDRAM; packet buffer size: 512 KB |
MIPS @ 264 MHz, 16 MB flash, 64 MB SDRAM; packet buffer size: 0.75 MB |
| Mounting |
| |
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
|
| Performance |
| Latency |
|
|
< 5.6 µs (FIFO 64-byte packets) |
| 100 Mb Latency |
< 4.9 µs (64-byte packets) |
< 4.9 µs (64-byte packets) |
|
| 1000 Mb Latency |
< 2.6 µs (64-byte packets) |
< 2.9 µs (64-byte packets) |
|
| Throughput |
up to 6.5 million pps (64-byte packets) |
up to 13 million pps (64-byte packets) |
up to 35.7 million pps |
| Switching capacity |
8.8 Gbps |
17.6 Gbps |
48 Gbps |
| MAC address table size |
8,000 entries |
8,000 entries |
8,000 entries |
| Environment |
| Operating temperature |
32ºF to 113ºF (0ºC to 45ºC) |
32ºF to 113ºF (0ºC to 45ºC) |
32ºF to 113ºF (0ºC to 45ºC) |
| Operating relative humidity |
15% to 95% @ 104ºF (40ºC), non-condensing |
15% to 95% @ 104ºF (40ºC), non-condensing |
15% to 95% @ 104ºF (40ºC), non-condensing |
| Non-operating/Storage temperature |
-40ºF to 158ºF (-40ºC to 70ºC) |
-40ºF to 158ºF (-40ºC to 70ºC) |
-40ºF to 158ºF (-40ºC to 70ºC) |
| Non-operating/Storage relative humidity |
15% to 95% @ 149ºF (65ºC), non-condensing |
15% to 90% @ 149ºF (65ºC), non-condensing |
15% to 95% @ 149ºF (65ºC), non-condensing |
| Altitude |
up to 10,000 ft. (3 km) |
up to 15,000 ft. (4.6 km) |
up to 10,000 ft. (3 km) |
| Acoustic |
Power: 0 dB no fan |
Power: 43.6 dB; DIN 45635T.19 per ISO 7779 |
Power: 40.3 dB |
| Electrical characteristics |
| Maximum heat dissipation |
68 BTU/hr (71.74 kJ/hr) |
92 BTU/hr (97 kJ/hr) |
164 BTU/hr (173 kJ/hr) |
| Voltage |
100-127 / 200-240 VAC |
100-127 / 200-240 VAC |
100-127 / 200-240 VAC |
| Current |
0.7 / 0.4 A |
1.2 / 0.7 A |
1.0 A |
| Maximum power rating |
20 W |
27 W |
|
| Power output |
|
|
48 W |
| Frequency |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
| Notes |
Maximum power rating and maximum heat
dissipation are the worst-case theoretical maximum numbers provided for
planning the infrastructure with fully loaded PoE (if equipped), 100%
traffic, all ports plugged in, and all modules populated. |
Maximum power rating and maximum heat
dissipation are the worst-case theoretical maximum numbers provided for
planning the infrastructure with fully loaded PoE (if equipped), 100%
traffic, all ports plugged in, and all modules populated. |
|
| Safety |
| |
cUL (CSA 22.2 No. 60950)
UL 60950-1
IEC 60950
EN 60950
|
cUL (CSA 22.2 No. 60950)
UL 60950-1
IEC 60950
EN 60950
|
cUL (CSA 22.2 No. 60950)
UL 60950-1
IEC 60950
EN 60950
|
| Notes |
| |
|
|
When using mini-GBICs with this product,
mini-GBICs with revision "B" or later (product number ends with the
letter "B" or later, e.g., J4858B, J4859C) are required.
|